Midwall™ Knee Wall Brace Kit 2-1/2" wall width x 24" height Structurally Rated Load Bearing
Code: KNEEWALLKIT-250-24- Product Details
- Half wall Tested wall brace for loading, cantilevered partial wall Rated Knee Wall Load Bearing Brace by Midwall™. Value Replaces labor/coordination of placing embedded angle into floor system Guide holes for attachment of MidWall to the stud Only certified steel is used 3.625" and 6" Meets IBC criteria Section 1607.7.1 Test data for 2.5" depth MidWall is available Anchors are by others and rating is determined by what bolt you use. Bolt used is based on recommendation of your engineer that specifies the wall. See Load Table tab for reference.
- Allowable Loads
- Product Data
Product Name:
MidWall™ Kneewall Steel Brace Kit.
US Patent #8,387,321
Distributer
Western Fabricating, LLC
Midwall™ is a product of The Steel Network
8805 Tamiami Trail North Ste 107
Naples, FL 34108
phone: (561) 295-1775
e-mail: sales@drywalltrims.com
web: www.kneewall.com
Product Description:
Midwall™ is a tested alternative in partial wall assemblies, designed to support out-of-plane loading in cantilevered partial wall systems that are unsupported at the top track.
The out-of-plane loads are transferred to the floor system through a 1/2" thick plate nested in the flanges of the member with two 3/8" diameter fasteners (or {one} 1.2" diameter fastener for 250MW) used for the connection.
Midwall™ 24" is generally used in interior half walls of less than 48" in height. Attach Midwall to 54 mil stud with #12 screws through all pre-drilled guide holes. Other studs in wall are typical infill studs.
Midwall™ 48" is used in interior half walls equal to or more than 48" in height. Use one Midwall 48" as a substitute for a stud at the specified spacing, or attach to a 54 mil stud with #12 screws through all pre-drilled guide holes.
Simple Installation:
Options:
Available in two lengths, 24" and 48". Midwall™ may be used in place of standard framing members, or in conjunction with them to frame a wall:
- 2-1/2" wall width x 24" height Rated
- 2-1/2" wall width x 48" height Rated
- 3-5/8" wall width x 24" height Rated
- 3-5/8" wall width x 48" height Rated
- 6" wall width x 24" height Rated
- 6" wall width x 48" height Rated
Design Information:
Criteria
- IBC2009
- Refer to Section 1607.7.1
- Handrails and Guards
- Interior Half Walls
- Parapets
- Ribbon Windows
- 50 lb/fy applied in any direction at the top of wall
- 200 lbs applied in any direction at any point at the top of wall.
- Design and Wind Pressure
- Design internal pressure
- ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H), 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, G90 (Z275) hot-dipped galvanized coating. Material Thickness = 118mil (10 gauge, 0.1242" design thickness) for 250MW and 362MW. Material Thickness = 97mil (12 gauge, 0.1017" design thickness) for 600 MW.
- ASTM A36/A36M: 36ksi (250MPa) minimum yield strength, 58-80ksi (400-550MPa) tensile strength, 1/2" minimum thickness.
Applications:
Handrails and Guards
Parapets & Ribbon Windows
Interior Half Walls
Material Composition:
MidWall
MidWall Plate
The top track spanning between Midwall members acts as a load distribution member capable of distributing localized loads to multiple MidWall members. It is recommended to design track in these applications. Refer to the diagram above for an example of the distribution of the point load, P, to adjacent MidWall supports. At the end of the wall, Midwall is required at adjacent stud spacings. Designed spacing begins after two adjacent end supports.